Testing inspection
Amalgamated adhere to strict quality control procedures to ensure best quality products. Following tests are carried out to ensure strength and best quality.

Visual Inspection.
Destruction Load Test.
Deflection Test.
Drop Test.

All types of cable trays are tested for flammability as under.

1. Classification of Flammability as per appendix - K of IS 6746.
2. Time and Rate of burning as per ASTMD 635.
3. Vertical burning test as per UL VD 94.

Cable trays are tested for surface burning characteristics as per ASTM EC4 / - IS 6746.

Tolerances
Dimensions of cable trays are with in the following tolerance

Length of trays + 6 mm
Inner width + 6 mm
Inner Depth + 6 mm
Hole Diameter + 1 mm
Thickness + + Open, - 0.5 mm
Local Variation in thickness 23 % of average thickness.

Applications

Chemical Plants
Refineries
Effluent Treatment Plants
Marine Industry
Food & Drug Industry
Metallurgical Plants
Off Shore Oil Platforms